WELCOME TO LAWSON!
LAWSON

Keywords:ultrasonic processor,homogenizer,Vortex mixer

LAWSON

News

News
Position: Home > News > Technical

Technical

Features and applications of cryogenic baths

Article source:LAWSON Author:Lawson Popularity: 173 Issuing Time:2018/4/18 9:58:54

The low-temperature thermostat is cooled by an air-cooled fully enclosed compressor unit, which has fast cooling speed, low noise and convenient operation. The cooling liquid in the tank can be led out to cool the experimental container outside the machine.

The cryogenic thermostat has an over-temperature alarm system to ensure the safety of the instrument. Touch the soft key to quickly set the temperature, which is easy to operate. Window LED digital display temperature measurement value and temperature set value. The microcomputer of the low temperature constant temperature bath corrects the deviation of the temperature measurement value, and the digital display accuracy is 0.01℃. Can do liquid level alarm and water discharge system.

Application of cryogenic thermostat:

Low temperature thermostat is used in chemical petroleum, medical biology, physical chemistry, metrology, colleges and universities, scientific research institutions, electronic instruments and other fields for experiments and inspections, as well as places where enterprises produce uniform temperature control of cold and heat. Constant temperature test, constant temperature tank control system: using PID automatic control, LED digital display, the external circulation pump can output the constant temperature liquid in the tank to the outside, establish a second constant temperature field outside the constant temperature tank, and expand the scope of use.

Cryogenic baths are widely used in chemistry, physics, biomedicine, petrochemical and other departments to conduct constant temperature tests on samples; cryogenic baths can also be used as heat or cold sources for direct heating or cooling and auxiliary heating or cooling. The temperature is set by LED digital, digital display; continuous PID automatic control of low temperature thermostat. The circulating pump can lead out the constant temperature liquid in the tank to establish a second constant temperature field; the low temperature constant temperature tank can also be used as a cold source (heat source) to lead the refrigerated (heated) liquid in the tank to lower (raise) the outside of the tank The temperature of the experimental container extends the range of use. The low temperature constant temperature tank adopts air-cooled fully enclosed compressor for refrigeration, which has fast cooling speed, low noise and convenient operation. The power supply is 220V, 50Hz.


    Copyright © 2003~2023 Ningbo Lawson Smarttech Co.,Ltd | Lawson·China | 浙ICP备15028117号-8